Logo
The Web's #1 Resource For A Slow Carb Diet!

If your pumping needs are large enough this can pay for itself, but it will be expensive to set up. (Although they will also allow an additional 5 kilowatts of battery inverter capacity.) 0000004736 00000 n A 5 kilowatt inverter will never supply more than 5 kilowatts of power no matter how many kilowatts of panels it has. Many Australian homes are not allowed to export more than 5 kW to the grid. We respect your privacy and you can opt out from the newsletter at any time. Most systems have mostly N facing panels, so really only generate peak power for a few hours a day (often 10am>2pm approx) One thing I find is that Voltage control works well: instead of the inverter resetting if the voltage gets too high, my inverters roll back output, so it actually helps my neighbors too because their inverters reset less often. I prefer a profile that just has the voltages set to a high voltage threshold, and if I have to sacrifice V-W mode, so be it. I am trying to get a system installed (6.5k smart hybrid inverter with a battery) and have been told by Western Power that I am limited to a 3.0 kva system. A small solar system can be financially viable. it is, kind of, effectively export limiting. Interesting article. At times MPPT1 is at 600 odd watts while MPPT2 is at 2500 odd watts. I know in the movie the Bad was worse than the Ugly, but thats not the way Im doing it. Here at SolarQuotes, we had been hearing quite a few complaints about Powercors zero export limits. The installer has been able to get the system through WP in the past as the inverter can limit the export to grid to 3kva. What Happens to the Surplus Power That Can't Be Exported to the Grid? What inverter do you have? I think is is utter madness that the VIC government is handing out generous rebates of $1850.00 and 4 year interest free loans of up to $1850.00 and Powercor has zero feed in capacity for excess solar power. 0000009027 00000 n Solar and renewables for installers / RECs - Jemena Powercor says the Solar Hotspots initiative is the first stage of a five-year Future Networks program to support customer investment in solar power systems, electric vehicles and battery storage. Have I been conned into believing I could produce up to 6.6kW myself, but in fact the maximum my inverter will ever allow through to the meter (and to my house) is only 5kW? Many NSW rural situations are limited to 3Kw export, due to the length of the transmission lines. But you probably would not recover the cost of the battery within its lifetime. . If that is the case it seems counter intuitive to me as I dont know if demand will outstrip production until I actually turn the appliance (eg A/C) on and check the display. I did get on the FiT in the early days for the 66cpkWh, but installed a separate system (which I have since incorporated into my stand-alone system. While the Envoy is an important part of the system, the micros largely operate independently of the Envoy, and in a lot of cases can work without the Envoy at all. Thus if my system is at maximum output, and I am using 2kW, only 3 kW is being exported to the grid. I have seen my panels producing over 13 kW of power when the battery is drawing 3 kW DC power and the battery, house and car 10 kW of AC power. Unfortunately, SAPN wont allow more than 5 kilowatts of inverter capacity on an SWER line. Up until quite recently, Powercor had been informing a large proportion of households looking to install new solar systems they will have to cop a zero export limit due to high congestion created by exports from existing systems. 0000001260 00000 n If they face in two or more directions, it will further reduce the losses by reducing the peak solar output while stretching it out, so it lasts longer through the day. I was really keen for this system with a battery as most of my power is used at night and I like the idea of power during blackouts, which do happen quite a lot here. An option is to take your pumps off-grid and run them independently off a separate off-grid solar system. But a sub optimally configured grid sometimes forces installers into implementing setting that are probably less than ideal if the high voltage events in the grid were just occasions where there is too much generation and they do want have all generators throttle back to allow some time for rebalancing supply and demand. 60% lagging Energex doesnt automatically allow inverters over 5 kilowatts to be installed with export limiting, but currently regularly grants permission for single-phase homes on the main grid to install up to 10 kilowatts of inverter capacity with export limiting. 0000007057 00000 n 207 The solar installer or customer must have sought and received pre-approval from us for the requested capacity of the generator. I have previously posted (or, submitted for posting), the proposition that what is needed, is a hybrid (not meaning in this instance, a hybrid inverter as is commonly used) inverter that is like a cross/combination, of the Goodwe GW5000-MS inverter (or, kind of, the GW10K-MS, in terms of power conversion), and the Goodwe GW5048D-ES; three GW5000-MS provides for up to 10kW of panels generating capacity, across three MPPTs (strings? Thank you. It can also only provide this when it is running. 0000005359 00000 n Just last week, Powercor (Western Victoria) advised that they now have more room in the grid for export. The Good: In these locations, properties can usually install up to 10 kilowatts of solar inverter capacity if they have single-phase power and up to 30 kilowatts with 3 phase power. When an inverter is export limited, it has to know how much solar energy is being sent into the grid so it can immediately reduce output if its about to go over the limit. 0000037764 00000 n Thanks. Weve seen a rapid growth in rooftop solar systems.With each installation, were facilitating rapid growth in the amount of solar capacity on our network. But it seems the situation has been changing for the better in the last couple of months in a number of affected areas. So the size of the system becomes irrelevant if you can only export 3kwh (we are Regional NSW Essential Energy). Thanks Ron. The installation of solar photovoltaic systems as well as the correct inverter settings are critical to ensuring customers get the most for their investment in this technology. 2. But if you dont use much electricity it may need to be very small, as I explain here: https://www.solarquotes.com.au/blog/zero-kw-export-solar/. Why my Power Limit is set to ON with the % whereas her Power Limit is set to OFF and she has been exporting. Seem most solar places, even the ones the go on about how good they are, arent that good when presented with this, what seems to be a conundrum for them. And yes 5kW export limit applies May I suggest an extra fact check to polish the valuable story above? When a home is exported limited, all the power the solar inverter can produce is available for the home to use. Theyd be higher for a sunnier location such as Perth and lower for cloudier places such as Melbourne or Hobart. Phone, email, give us feedback or make a claim. Solar export limiting, or 'export limiting', occurs most often when there is more power being pushed into the grid than it can handle. Though endless quibbling over unnecessary details might keep the presses churning, a FACT remains that Ive been using ever-more-cost-effective batteries since 1980. Would the gateway signal the micro inverters to shut down one at a time, or to all reduce output equally? Anyway you are probably not supposed to be messing around with the profiles without agreement of your DNSP. And also is it worth installing solar with 0 kWh limit with self consumption around 20-30%( payback 6-7 years). If a home cant export any power at all then there is no financial reason to install a large solar system. amended or replaced from time to time. Where do I find information on reapplying for export with Powercor? We want to add a battery and it seems logical to add more cells also to another inverter/battery setup. 0000037380 00000 n I am looking at adding a second system (6.2kW) with GoodWe inverter. I just dont understand it. Please confirm the maximum export limit in the relevant section of this application.. 0000022631 00000 n Solar connections for industry | CitiPower & Powercor Plus a Tesla Powerwall 2. I realise that all the political parties in the the WA state parliament and especially, the Synergy/Western Power conglomerate, that controls approvals of domestic rooftop photovoltaic systems connected to the SWIS grid, are opposed to domestic rooftop photovoltaic systems (even though we stabilise and sustain the grid), but, I am wondering whether any reason has ever been given by the oppressive authorities, for banning export limited inverters in WA. 100% endstream endobj 351 0 obj <>/Filter/FlateDecode/Index[17 289]/Length 31/Size 306/Type/XRef/W[1 1 1]>>stream For any amount above the daily export, you will receive our standard retailer feed-in tariff of 5 . hb```f``sd`c`edd@ A >hp`86s8::\ MNmOe0pYuR`i g G7@ $n@]A#&S_2.dx f In my mind though the Smart meter at the box would adjust the export limit in line with what the house is consuming? 20% NSWs Ausgrid Network Area: This covers East Sydney, Newcastle, and out to Merriwa. 4. While losses increase as the solar power system size goes up, even with 10 kilowatts of panels which is twice the export limit, only 13% of generation is lost. This is disappointing as this would be an easy option to implement. But you will probably find that there is another setting that it will shutdown when 10 minute average voltage is a measly 255v. Since in WA you cant have more than a 5kW inverter on a private residence, I believe there isnt actually export limiting in play, and the inverter itself clips the output AC regardless how much the panels are generating, sadly. I havent made any applications yet, but Ill certainly be asking this question when I get quotes!. 0000006578 00000 n This is assuming that my understanding of what I have read, is correct; that such a system would be permitted, in a single phase connection to the SWIS grid. Swearing revenge, he began his lifelong quest to reduce the harm the environment could cause. 253 hour of charging is enough to drive 35km.. Assume positive intention.4. 100% I have a 14kW solar array running Enphase IQ7+ microinverters (43 of them) hooked up to the grid in a 3-phase configuration in the Endeavour Energy area in NSW, and they currently have the profile AU default AS4777.2:2015 30kVa, Vv, Vw set. The fact is that Powercor does not set an upper limit on the size solar panel system you can install, up to 30kW. We are on a zero limited export. The standard relating to solar inverters is about to change. 0000037497 00000 n 0000027818 00000 n Because you dont see the rather obvious shutdowns (or see them less), you might not notice your solar might be throttled back on a regular basis. This gives the advantage of having a new system covered by a new set of warranties. endstream endobj 307 0 obj <>/Metadata 15 0 R/Pages 14 0 R/StructTreeRoot 17 0 R/Type/Catalog/ViewerPreferences<>>> endobj 308 0 obj <. We are in an area where only about 20% of the homes have solar. Of more concern is occasional spikes in consumption which go past the 5kw limit. Even if you have the Envoy-S, I believe at least on paper there was a Enphase Envoy-S Rooftop solar works by turning sunlight into electric power. As a side issue for you, if you (like lots of people) have high voltages issue causing shutdown / throttling, I am not a big fan of the Volt-watt modes, as often these modes will also lower the voltages at which the throttling kicks in. at night or not enough at day time ? just wondering if anybody can shed some light on the following, In future, will powercor allow export limit if they upgrade transformer? It also allows you to focus on increasing your self consumption which in turn provides a better return on investment. We do not prevent customers from installing solar for their own self-consumption. But given average voltages are probably well above what they should be in lots of places, and once you factor in your local voltage rise, and pretty low values under AS4777 etc, there is not much room to play with until the distributors get the act together and deliver us power that better matches the 230v standard they are required to deliver us. 207 It would definitely be better if we didnt need to limit the amount of power solar systems sent into the grid. 11kW panels with 10kW 3-phase inverter (Fronius Symo + Fronius 3-phase meter). Solar Export Limiting Explained -- What It Is & Why It's Useful Energex doesnt automatically allow inverters over 5 kilowatts to be installed with export limiting, but currently regularly grants permission for single-phase homes on the main grid to install up to 10 kilowatts of inverter capacity with export limiting. But this is at least partially because when you throttle back output, you also reduce the amount of voltage rise you are causing on your local connection to the point of interconnect which is probably contributing to the issue. Limited export means more power for home If your system has a limit on how much it can export then it means more power will get used in your home instead. . It is delivering 8 kilowatts of solar power. Enter your postcode now. MPPT2 always shows better performance than MPPT, usually quite significantly better. Powercor's technical assessment aims for these works to enable at least 80% of new solar applications to export 5 kW. 306 0 obj <> endobj Now, that would help protect electricity grids, especially, the fragile, decrepit SWIS grid, for the present. JackD 1 year ago. The current Envoy they will be selling is the Envoy-S. Before that was the straight Envoy which did not have the consumption monitoring / metering needed to do export limiting. Voltage (V) measured at inverter terminals Its also unusual for a large solar system to have all the panels facing the same direction. This is done for three main reasons: In this article, Ill give a broad outline of how export limiting works and why it can be a good idea. 0000007554 00000 n Im glad to hear its flexible enough to do that. Max. Powercor households stand to save even more with solar The MSO helps us manage and keep our network safe for solar customers. is it 10kW AC or DC?? The inverter reduces the amount of electrical energy supplied by the solar panels. Your meter is on the connection between the mains network on one side and the combination of your inverter and your loads on the other side. 2. So if an inverter that is export limited to 5 kilowatts is providing 8 kilowatts of power, none of it will go to waste provided the home is consuming at least 3 kilowatts at the time. The power is first used to meet household consumption, with any surplus exported to the grid for other people to use. Actually I made a chart showing the percentage of electricity lines in each state that were SWER but I left it out for the sake of brevity. Or is there a build up of voltage in the system? Hi All. Depending on their location, some may be constrained to a lesser export level or even no exports at all. Please stay on topic. But I will warn you, even with the high cost of grid electricity and the low solar feed-in tariff in Western Australia, batteries normally wont pay for themselves. The earth is used as one conductor which has a higher resistance than a copper wire. (We are conected to a 25Kw transformer, with 5 consumers connected.). (2nd one APPROVAL/SITE SPECIFIC CONDITION(s): Total Solar Export must be limited to 5kW). Will this mean any additional system would be limited to 0kW output?? But whether or not extra solar capacity will pay for itself is another matter. To get your quotes, please enter your postcode: AEMC: Electricity Prices To Continue To Fall, http://www.johnrogers.com.au/battery_charging_noon.jpg, http://www.solarquotes.com.au/blog/kw-and-kwh-what-is-the-difference/, Why Australian Solar Installers Love Austrian Fronius Inverters, Tesla Powerwall Price Takes A Tumble In Australia, "Snail Mail" Home Battery Offers: Be Wary, New Minimum VIC Solar Feed-In Tariffs Locked In, Glenrowan Solar Farm Construction Gets Cranking. South Australia Power Networks (SAPN) area: SAPN is the only distributor in South Australia. We just had a 30kW inverter solar install for our business and it has been limited to 1.8kW export. Victorias CitiPower area: The Melbourne Central Business District. He's been reporting on Australian and international solar energy news ever since. I was always of the belief that a 5kW inverter limited the total output/ production from my 6.5kW solar system to 5 kW, irrespective of what is being used in the house. Powercor claims 30% increase in rooftop solar export approvals Victorian network service provider Powercor claims a major works program designed to alleviate grid congestion in areas of high rooftop solar PV penetration has boosted the approval rate for new solar connections to export excess energy to the grid by an impressive 30%. %PDF-1.4 % Very true AL0126. But your situation is complicated by already having a 3 kilowatt system.

Strange Bird Calls At Night Uk, Motion To Dismiss For Insufficient Service Of Process, Articles P

powercor solar export limit